Zobrazit stránku 12
Using SQL Server 2012 Column-Store with SAP BW
SAP COMMUNITY NETWORK scn.sap.com
© 2012 SAP AG 13
The column-store configuration can either be an explicit configuration for a particular cube or an implicit
configuration using the system default. Valid configuration values are:
"NONCLUSTERED"
for cubes having a non-clustered column-store index
" " (an empty field)
for cubes not having a column-store index
Note: You may also see in SE16 the configuration value "NOT_SUPPORTED". This indicates that a cube was explicitly
configured to use the column-store. However, it cannot use it, because it includes a key figure with high precision.
The configuartion values are stored in table MSSSTORAGE in field TEXT.The field TABNAME contains the
name of the e-fact table for an explicit column-store configuration of a cube. The system default is also
stored in table MSSTORAGE with TABNAME = "&GLOBAL_EFACT"
In the example above, all cubes are configured implicitly to use the column-store, except for the following
four cubes: COPY_BNE, COPY_BPE, PERF_BTE, PERF_BTF.
Cube 0CCMSAMEM (with e-fact table /BI0/E0CCMSAMEM) is configured to use the column-store index due
to its explicit configuration in addition to the system default. It is useful to store the explicit configuration to
keep the cube unchanged, even if you will change the system default in the future.
If there is no row with TABNAME = "&GLOBAL_EFACT" in MSSSTORAGE, then the system default is, not
to use the column-store index.
By pressing F3 (green arrow back), you can return to the main screen of report MSSCSTORE
Configure single cube
In the tab Process single cube you have to enter the cube name (not the name of the e-fact table) that you
want to configure. To get a list of all cubes, you can use the F4 help. Alternatively, you can type the cube
name manually in the input field.